RIDEC 5000 Protocol

 

SERIAL COMMUNICATION PROTOCOL V1.4X

The communication is made through a serial protocol in ASCII format, according to the programming, 8 bits, no parity, one stop bit, no handshake and 9600 baud. The bite of the CRC is transmitted if this selected the protocol RS485

 

CONTINOUS READ COMMAND

It is used to configure the RIDEC5000 for continous reading of the tags near the reader antenna. The reader returns nothing when there is no tag near the antenna, and the tag memory contents when it is correctly read.

         Command: cxx

Where xx is the block number to be returned in hex format (00 to 3F).

 

RIDEC5000 Answer:

  • For block number 00, 8 bytes (corresponding to the complete serial number)+CRC+CR+LF.

  • For blocks between 0x01 and 0x0F, 4 bytes (corresponding to the block) +CRC+CR+LF.

  • For blocks between 0x10 and 0x1F, the whole tag content (as selected in the block reading param.)+CRC+CR+LF.

  • For block number 0x20, 8 bytes (corresponding to the complete serial number) +CRC+CR+LF.

  • For blocks between 0x21 and 0x2F, 4 bytes (corresponding to the block) +CRC+CR+LF.

  • For blocks between 0x30 and 0x3F, the whole tag content (as selected in the block reading param.)+CRC+CR+LF.

If there is not any detected tag, the RIDEC5000 will not return anything. The RIDEC5000 leaves continous read when it receives any character throug the serial port.

 

READ COMMAND

The RIDEL5000 attempts the reading of a tag once. If the block number ranges between 0x00 and 0x1F, the RIDEC5000 will try to read the tag. If the tags is correctly read, it will return its contents. If there is no tag, nothing will be returned. In both cases, the RIDEC5000 will wait for a new command.

If the block number ranges between 0x20 and 0x3F, the RIDEC5000 will wait for a tag to be correctly read, returning ist contents, and waiting for a new command.

          Command: rxx

Where xx is the block number to be returned in hex format (00 to 3F).

 

RIDEC5000 Answer:

  • For block number 00, 8 bytes (corresponding to the complete serial number) +CRC+CR+LF.

  • For blocks between 0x10 and 0x1F, the whole tag content (as selected in the block reading param.)+CRC+CR+LF.

  • For block number 0x20, waits for the tag and returns 8 bytes (corresponding to the complete serialnumber) +CRC+CR+LF.

  • For blocks between 0x21 and 0x2F, it waits for the tag, and returns 4 bytes (corresponding to the block) +CRC+CR+LF.

  • For blocks between 0x30 and 0x3F, the whole tag content (as selected in the block reading param.).

If there is no tag detected, the RIDEC5000 will return the sequence N+CR+LF, and it will wait for a new command.

 

CRC CALCULATION

The CRC value is calculated as the Exclusive or of 5A and all the received data (not including CR or LF).

 

I/O PORT CONTROL

The reader includes 4 ports configurables as inputs or outputs, under software control.

           Command (ASCII CHARACTER): pxy

Where x define, in a bitwise mode, the direction of the corresponding port (1 means output and 0 means input). The LSB corresponding to the port 0. As an example, x=2 (hexadecimal) or 0010 (binary), will configure the ports 0, 2 and 3 as inputs and port 1 as output.

The parameter y define, in a bitwise mode, the logic level if the port is configured as an output. If it is an input, a 1 will configure the input with an internal pull-up.

 

Answer:

The reader will answer with the string: xyzw

Where x and y are the operators sent with the command, z corresponds to the logic level of the outputs, and w corresponds to the logic level of the inputs.

 

VERSION COMMAND

It returns the RIDEC5000 version information.

          Command: x

RIDEC5000 Answer:

Version number+CR+CF.

 

WRITE COMMAND

It writes the four bytes (32 bits) corresponding to the selected block. It returns the answer from the tag, if the writing is succesful.

          Command: wyyxxxxxxxx

Where yy is the block number to be written (from 0x00 to 0x0F), and x are the data corresponding to the selected block (4 data 8 bits each). It is important to consider the following information.

The block 00 and 01 correspond to the serial number, so they are read only.

The block number 02 contains the write permission data for the different blocks of the tag. They have to be carefuly writen, in order not to permanently disable the tag for writing.

 

RIDEC5000 Answer:

If the writing is succesful, the RIDEC5000 will answer Yw+CR +CF.

If there is any error, or there is not any tag present, the RIDEC5000 will answer Nw +CR +CF.

 

RESET QUIET

This command resets a tag with the QUIET mode active. The QUIET bit is in the block 3, byte 0, bits 3 and 4. A 11 written to this position, will put the tag in QUIET state. It will stay in this mode until a Reset Quiet command is received.

          Command: q

The RIDEC5000 will not send any answer.

 

Connection

RS232 Version

1. +6,5 a 9Vcc

2.- Ground

3. Power down

4. RTS

5. RXD

6. TXD

7. PD3

8. PD4

9. PD2

10. PD1

RS485 Version

1. +6,5 a 9Vcc

2. Ground

3. Power down

4.

5. A

6. B

7. PD3

8. PD4

9. PD2

10. PD1

 

TTL Version

1.- +6,5 a 9Vcc

2.- Ground

3.- Power down

4.-

5.-Reception

6.- Transmission

7.- PD3

8.- PD4

9.- PD2

10.- PD1

 

RIDEC 5000 Version Coding

RIDEC5000xy

Where x correspond to the communication bus:

A = RS232

B = RS485

C = TTL

And y is the power supply range:

A = 3.5 to 5V

B = 6 to 9V

The standard manufactured models are:
 

RIDEC5000AB RS232 6 to 9 Vcc

RIDEC5000BD RS485 6 to 9 Vcc

RIDEC5000CA TTL 3.5 to 5Vcc

Ask for availability of other versions.

TECHNICAL SPECIFICATIONS

Operating Frequency

13,56 MHz. 

Air protocol

I-CODE (Tag-it, Mifare, Legic, PicoTag upon request)

Operating range

8 cm (with built-in antenna) 

Output ports

4 TTL low current 

Mute    

0 Power 

Communication bus

 

Version A

Serial RS232 

Version B

Serial RS485 

Version C

Serial TTL 

ID Key for RS485

4 Bites x 8 bits

Protocol options

ASCII or binary 

 

With or W/out access key

Baud Rate

9.600, 14400, 19200, 28800, 38400, 57600

Voltage Supply range

 

A version

3,5 to 5 Vcc

B version

6 to 9Vcc 

Current consumption

 

A version

@ 3,5 Vcc 48mA

 

@ 5 Vcc 80mA 

B version 

@ 6 Vcc 74mA 

 

@ 9 Vcc 93mA 

Factory settings

   

Access Key

30 31 32 

Data format

ASCII 

Baud Rat

9600 Bauds 

Protocol

RS232

 

No access Key

Block Read

00 64 

 

Mechanical Dimensions

 

 

 

Go to

RIDEC 5000 Data Sheet